TM 9-4940-421-14
LOCATION
NOT FULLY MISSION
ITEM TO
PROCEDURE
INTERVAL
CAPABLE IF:
CHECK/SERVICE
Any of the outlets are
CIRCUIT BREAKERS AND RE-
During oper-
dead, or if circuit break-
CEPTACLES. Check that electrical
ation, but not
ers cut off for no reason,
current is delivered to the four recep-
less frequent-
or if circuit breakers are
tacles on the control panel (p. 22),
ly than
difficult to turn on and
the receptacle next to the air compres-
monthly
off.
sor starter box (p. 23), and the exter-
nal power receptacle (p. 2-4). Check
that circuit brokers operate easily
and do not cutoff for no reason.
Notify organizational maintenance if
not working properly.
SERVICE LIGHT. Turn on, then turn
off service light. Notify organization-
al maintenance if service light is not
working.
Welder will not perform
Welder
Perform straight stick welding
During oper-
its function at all switch
(p. 2-4) or otherwise apply a load at
ation, but not
settings.
all settings of DC ampere selector
less frequent-
switch and DC ampere adjusting
ly than
rheostat. Notify organizational main-
monthly
tenance if welder is not functioning at
all settings.
Air compessor will not
During oper- Pressure Gage
come on and buildup
ation, but not Reading
observe reading on pressure gage
normal pressure of 80-
(p. 2-3) while checking that the com-
less frequent-
100 psi (551.60
ly than week-
pressed air system delivers a steady
689.50 kpa), or if com-
flow of air. If correct pressure range
ly
pressed air delivery can-
cannot be reached, adjust the pressure
not be maintained at this
switch (p. 23) as follows:
pressure, or if presure
switch cannot be prop-
a. Low cutin pressure: 75 85
erly adjusted, or if pres-
psi (517.13 586.08 kpa).
sure gage is inoperative.
b. High cut-out pressure: 95
105 psi (655.03 689.50 kpa).
If switch cannot be set to correct pres-
sure, notify organizational mainte-
nance.
Change 1
3-2.7