WARNING
Fall hazards that may cause injury or death exist when climbing onto, returning from or
working from the top of the container. Always maintain three points of contact (two feet
and one hand, or one hand and two feet) with the folding steps and roof access handle
when climbing onto the ASLMS container. All movement should be in the forward
direction. Never move, step, or walk backward when working on top of the system. A fall
can occur if a worker loses concentration and steps backward off the edge. Stand erect
only if necessary, and only away from the edge. Working from a kneeling position helps
reduce the threat of a fall. Access to roof by forklift or other MHE is forbidden.
3.
To install the upper horizontal interconnectors, access the roof via the roof access system in the end
of the FPU-12.
4.
Insert horizontal interconnectors in the two top ISO corner block openings of the FPU-12 container.
5.
While holding the horizontal interconnector in place, tighten the bolt in the interconnector body closest
to the FPU-12 until seated firmly using a 9/16-inch hex socket, 2 -inch long extension and -inch
square drive flex head wrench. The bolt will be recessed and flush with the connector housing when
complete.
WARNING
Make sure all container connectors are properly seated and secured. Failure to comply
could cause serious injury, death, or property damage.
6.
After the two upper horizontal interconnectors are secured in place climb from the roof via roof
access system.
7.
Insert horizontal interconnectors into the two lower ISO corner block openings in the FPU-12
container.
8.
While holding the horizontal interconnector in place, tighten the bolt in the interconnector body closest
to the FPU-12 until seated firmly using a 9/16-inch hex socket, 2-inch long extension and -inch
square drive flex head wrench. The bolt will be recessed and flush with the connector housing when
complete.
Change 1