TM 10-5411-236-13&P
0047 00
REPLACE
Replace broken vent cover release assembly as follows:
1. Ensure vent cover (1) is in the closed position.
2. Disconnect the release cable from the vent cover release assembly (2) by removing the cable stop.
3. Remove two each 1/4-inch hex head bolts and nuts (3, 4) from the vent cover release assembly (5)
using a 7/16-inch socket and ratchet.
4. Attach the new vent cover release cable to the vent cover release assembly by feeding cable through
release lever and reattaching the cable stop.
5. Attach the new vent cover release assembly (5) to the container with two each 1/4-inch hex head
bolts using a 7/16-inch socket and ratchet. Do not tighten these bolts.
6. To align, pull the reset handle until the vent cover is locked in the open position.
7. Tighten the two each 1/4-inch hex head bolts and nuts (3, 4) using a 7/16-inch socket and ratchet.
1
2
5
3, 4
0047 00-2