TB 9-4940-302-30
4.
Installation--Continued
and mark and drill three 0.22-in.
diameter holes in back of case. Posi-
over installed blind rivet nuts.
Secure mounting bracket to wall using
and 4. Secure to wall using three #10
three #1O x 1-in. countersunk head
x 1-in. countersunk head machine screws
machine screws (MS35190-275). Install
(MS35190-275). Install contents of
fire extinguisher in mounting bracket.
first aid kit.
(16) Before installing first aid
INSTALLATION IN IS0-2-1 SHELTER
(1) Mark and drill six 0.25-in.
5.
Installation
diameter holes in right side wall, in
NOTE
of 1.00-in. maximum. Inject potting
Hand blind riveter (5120-00-
compound as required and install six
679-6523) is used to install
blind rivet nuts in floor
#10 blind rivet nuts (11021235-5).
and walls of IS0-2-1 shelter.
Hand blind riveter (5120-00-
(2) Mark and drill eleven 0.41-
357-6065) is used for instal-
in. diameter holes in fixed floor and
ling blind rivets (MS20601).
right side wall in accordance with
Install blind rivet nuts in
accordance with MIL-N-47187.
in. maximum. Inject potting compound
as required and install nine 5/16-in.
Position storage cabinets,
blind rivet nuts (11021235-1) in ac-
14-in. bed and 30-in. bed
industrial sewing machines,
Install two 5/16-in. blind rivet nuts
(11021235-3) in accordance with figure
extinguisher as shown in
10.
15. Use the equipment
mounting holes as template
Install nine 5/16- x 2-7/8-in.
b.
for location of blind rivet
shoulder eyebolts (MS51937-2) in blind
nuts. Positions may be
rivet nuts marked "A" and "B" in floor
varied to drill into structural
in accordance with figures 9, 10, and 13
members in fixed floor.
and secure with nine 5/16-in. lock-
washers (MS35338-45) and nine 5/16-in.
Follow steps (1) and (2) for in-
hex nuts (MS51967-5).
stalling blind rivet nuts in the ISO-2-
1 shelter, unit 2.
NOTE
Eighteen 5/16-in. blind
CAUTION
rivet nuts exist in the
After installing blind rivet
floor of the IS0-2-1 shelter,
nuts, potting compound
five of which are used for
component installation
a curing time of 24 to 48
hours before using any
threaded fasteners.