MAINTENANCE INSTRUCTIONS FOR EYEWASH STATION ASSEMBLY BRACKET AND HARDWARE - Continued
Figure 2. Wall and Floor Insert Inspection.

Operator Manual \(Rpstl\) For Pneudraulic Shop P/N Sc4920-99-Clc64 And Part No 1036258
Page Navigation
  171    172    173    174    175  176  177    178    179    180    181  
img
. .
TM 1-4920-433-13&P
0046 00
FIELD MAINTENANCE
PNEUDRAULIC SHOP
MAINTENANCE INSTRUCTIONS FOR SETSCREWS AND INSERTS
INITIAL SETUP:
References
Tools and Special Tools
TM 10-5411-201-14
General Mechanics Tool Kit
(WP 0062 00, Table 2, Item 104 )
Equipment Condition
Personnel Required
Functional
CMF 15 Series (1)
INSPECTION OF INSTALLED ITEMS
SETSCREW INSPECTION
Figure 1.
Setscrew Inspection.
1.
Remove any setscrew (Figure 1, Item 1) that will not screw into loor insert (Figure 1, Item 2).
2.
Inspect setscrew (Figure 1, Item 1) and insert (Figure 1, Item 2) for damaged threads.
3.
Install new setscrew (Figure 1, Item 1) as required.
0046 00-1