• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
MAINTENANCE INSTRUCTIONS FOR FIRE EXTINGUISHER BRACKETS AND HARDWARE - Continued
Figure 2. Hose Clamp Removal.

Field Maintenance Manual For Sheet Metal Shop Part No. 1035658 And Part No. Sc4920-99-A68
Page Navigation
  247    248    249    250    251  252  253    254    255    256    257  
img
. . .
TM 1-4920-435-13&P
0064 00
FIELD MAINTENANCE
SHEET METAL SHOP
MAINTENANCE INSTRUCTIONS FOR OIL/WATER SEPARATOR
INITIAL SETUP:
Tools and Special Tools
Personnel Required
General Mechanics Tool Kit
CMF 15 Series (1)
(WP 0072 00, Table 2, Item 104 )
Equipment Condition
Torque Wrench, 0-600 in. lbs
Functional
(WP 0072 00, Table 2, Item 109 )
WARNING
Ensure compressed air supply is disconnected before attempting any work on oil/water sep-
arator. Do not direct compressed air near eyes or directly against skin. Wear goggles; high
pressure air against eyes can cause BLINDNESS.
NOTE
During installation of components same hardware should be used so as to maintain the original
integrity of the shop sets.
INSPECTION OF INSTALLED ITEMS
NON-METALLIC HOSE AND FITTINGS
Figure 1.
Inspect Hose and Fittings.
1.
Inspect non-metallic hose (Figure 1, Item 1) for visible damage.
2.
Replace if damage is detected.
0064 00-1