Figure 2. Inspect 45 Degree Angle Adapter.
Figure 5. 45 Degree Angle Adapter Removal from Power Entry Panel Cover.

Maintenance Manual For Engine Shop Part No. 1035258 And Part No. Sc4920-99-Cla60
Page Navigation
  183    184    185    186    187  188  189    190    191    192    193  
img
0046 00
TM 1-4920-436-13&P
REMOVAL CONTINUED
1.
Move main circuit breaker to OFF position.
2.
Remove four machine screws (Figure 3, Item 1) attaching 60 amp receptacle (Figure 3, Item 2) to 45 degree
angle adapter (Figure 3, Item 3).
3.
With machine screws (Figure 3, Item 1) removed, pull 60 amp receptacle (Figure 3, Item 2) out of 45 degree
angle adapter (Figure 3, Item 3) until wire lug terminals (Figure 3, Item 5) and wires (Figure 3, Item 4) are
exposed.
Figure 4.
45 Degree Angle Adapter Replacement.
NOTE
Receptacle lugs are identiied by letters "X", "Y", and "Z" with ground connection being identiied
by color green. Black wire will be attached to "X", red wire will be attached to "Y", and blue wire
will be attached to "Z".
4.
Loosen all lugs (Figure 4, Item 3) on 60 amp receptacle (Figure 4, Item 1) and remove wires (Figure 4, Item
2).
0046 00-4