0050 00
TM 1-4920-436-13&P
REMOVAL
AIR FEED-THRU CONNECTOR ASSEMBLY
Figure 8.
Disassembly of Air Feed-thru Connector Assembly.
1.
Have assistant hold nut (Figure 8, Item 4) and washer (Figure 8, Item 2) inside shelter.
2.
Remove nuts (Figure 8, Item 4), lat washers (Figure 8, Item 2), lock washers (Figure 8, Item 3), and screws
(Figure 8, Item 1), releasing air feed-thru connector assembly (Figure 8, Item 5).
Figure 9.
Removal of Air Feed-thru Connector Assembly.
3.
Remove air feed-thru connector assembly (Figure 9, Item 2) from services utility panel.
4.
Remove old caulking compound (Figure 9, Item 1).
0050 00-6