MAINTENANCE INSTRUCTIONS FOR WATER AND AIR FEED-THRU CONNECTOR ASSEMBLIES
Figure 4. Water Feed-thru Connector Flange.

Aviation Maintenance Manual For Power Train Shop P/N 1036459 And P/N Sc492097Cla65
Page Navigation
  216    217    218    219    220  221  222    223    224    225    226  
img
0057 00
TM 1-4920-438-13&P
REMOVAL
WATER FEED-THRU CONNECTOR ASSEMBLY
Figure 2.
Disassembly of Water Feed-thru Connector Assembly.
1.
Have assistant hold nut (Figure 2, Item 5) and washer (Figure 2, Item 3) inside shelter.
2.
Remove nuts (Figure 2, Item 5), lat washers (Figure 2, Item 3), lock washers (Figure 2, Item 4), and screws
(Figure 2, Item 2), releasing water feed-thru connector assembly (Figure 2, Item 1).
Figure 3.
Removal of Water Feedthru Connector Assembly.
3.
Remove water feed-thru connector assembly (Figure 3, Item 2) from services utility panel.
4.
Remove old caulking compound (Figure 3, Item 1).