Figure 4. Water Feed-thru Connector Flange.
Figure 7. Inspect Air Feed-thru Connector Assembly.

Aviation Maintenance Manual For Power Train Shop P/N 1036459 And P/N Sc492097Cla65
Page Navigation
  218    219    220    221    222  223  224    225    226    227    228  
img
0057 00
TM 1-4920-438-13&P
INSTALLATION CONTINUED
WATER FEED-THRU CONNECTOR ASSEMBLY CONTINUED
Figure 6.
Attach Water Feed-Thru Connector Assembly.
3.
Install all but one screw (Figure 6, Item 2), have assistant install lat washers (Figure 6, Item 3), lock washer
(Figure 6, Item 4), and nuts (Figure 6, Item 5) inside of shelter and secure.
4.
Replace one lanyard (Figure 6, Item 6) on outside of shelter and install remaining screw (Figure 6, Item 2).
5.
Have assistant install lat washer (Figure 6, Item 3), lock washer (Figure 6, Item 4), second lanyard (Figure 6,
Item 6), and nut (Figure 6, Item 5) on inside of shelter.
6.
Tighten screws (Figure 6, Item 2).