ECU SECURITY SCREENS
Figure 2. Test Ground Rod.

Aviation Maintenance Manual For Power Train Shop P/N 1036459 And P/N Sc492097Cla65
Page Navigation
  233    234    235    236    237  238  239    240    241    242    243  
img
. . .
TM 1-4920-438-13&P
0062 00
FIELD MAINTENANCE
POWER TRAIN SHOP
MAINTENANCE INSTRUCTIONS FOR GROUND ROD
INITIAL SETUP:
Personnel Required
Tools and Special Tools
CMF 15 Series (1)
Electrical Repairers Tool Kit
Equipment Condition
(WP 0067 00, Table 2, Item 103 )
Functional
Multimeter (WP 0067 00, Table 2, Item 106 )
WARNING
HIGH VOLTAGE exists in electrical system of shop. All electrical inspections, repairs, or
replacements will be performed with power OFF and only by a qualiied electrician. Serious
shock hazards exist which could result in INJURY OR EVEN DEATH to personnel.
INSPECTION OF INSTALLED ITEMS
Figure 1.
Inspect Ground Rod.
1.
Move main circuit breaker to OFF position.
2.
Ensure ground rod (Figure 1, Item 1) is irmly driven into ground.
3.
Ensure electrical clamp (Figure 1, Item 2) and screw (Figure 1, Item 3) are securely fastened.
4.
Ensure there is no sign of oxidation around clamp (Figure 1, Item 2) or screw (Figure 1, Item 3).
5.
Ensure that ground cable (Figure 1, Item 4) is not frayed or broken.
6.
Move main circuit breaker to ON position.