Figure 3. Load Balancer Slide Stops, Upper Position.
Figure 5. Load Balancer Slide Stops, Lower Position.

Maintenance Manual For Production/ Quality Control Shop Part No. 1036659 And Part No. Sc4920-99-Cla66
Page Navigation
  17    18    19    20    21  22  23    24    25    26    27  
img
TM 1-4920-440-13&P
0005 00
SHELTER EXPANSION CONTINUED
WARNING
Expandable section (hinged loor and hinged sidewall together) weighs 700 pounds (318
kg). DO NOT stand directly in front of hinged section. Failure to observe warning could
result in SERIOUS INJURY to personnel.
Hinged loor support cables must be secured in cable housing guide prior to lowering
shelter loor. If support cables are not secured, support cables will remain under tension.
DO NOT attempt to remove cables if support cables are not secured. Removing cables
while under tension could cause SERIOUS INJURY to personnel.
Figure 4.
Cam Lock Handles.
4.
Raise cam lock handles (Figure 4, Item 1) on corner posts (Figure 4, Item 2) and rotate as indicated by stencil
to disengage hinged loor locks.
5.
Carefully lower hinged loor to extent of support cable travel (1 1/2 in. (3.8 cm) below level).