POSITIONING ECU (A) FOR TRANSPORT MODE - CONTINUED
PREPARING SHELTER FOR ECU STOWAGE

Maintenance Manual For Production/ Quality Control Shop Part No. 1036659 And Part No. Sc4920-99-Cla66
Page Navigation
  104    105    106    107    108  109  110    111    112    113    114  
img
. .
TM 1-4920-440-13&P
0030 00
OPERATOR INSTRUCTIONS
PRODUCTION/QUALITY CONTROL SHOP
POSITIONING SHELTER BII BOX FOR TRANSPORT MODE
INITIAL SETUP:
Personnel Required
Tools and Special Tools
General Mechanics Tool Kit
CMF 15 Series (2)
(WP 0063 00, Table 2, Item 104 )
Equipment Condition
Functional
POSITIONING SHELTER BII BOX FOR TRANSPORT MODE
Figure 1.
Secure Shelter BII Box.
1.
Remove two setscrews from shelter BII box transport location loor inserts and store in shelter BII box (Figure
1, Item 2).
2.
Remove one cargo strap (Figure 1, Item 3) from secure storage location and two ring bolts (Figure 1, Item 1)
from shelter BII box (Figure 1, Item 2).
3.
Install two ring bolts (Figure 1, Item 1) into loor inserts at transport location.
4.
Secure shelter BII box (Figure 1, Item 2) with cargo strap (Figure 1, Item 3) and two ring bolts (Figure 1, Item
1).
END OF WORK PACKAGE