POSITIONING ECUS FOR TRANSPORT MODE
POSITIONING ECU (B) FOR TRANSPORT MODE - CONTINUED

Maintenance Manual For Production/ Quality Control Shop Part No. 1036659 And Part No. Sc4920-99-Cla66
Page Navigation
  100    101    102    103    104  105  106    107    108    109    110  
img
. . .
0029 00
TM 1-4920-440-13&P
DISCONNECTING POWER FROM ECUS - CONTINUED
1.
Set MODE switch (Figure 1, Item 2) on ECU (B) (Figure 1, Item 1) to OFF position.
2.
Unscrew connector lock ring (Figure 1, Item 4) from power input receptacle (Figure 1, Item 6).
3.
Pull end of connector (Figure 1, Item 5) from power input receptacle (Figure 1, Item 6).
4.
Store power cable (Figure 1, Item 3) in secure storage location.
5.
Install protective dust cap (Figure 1, Item 7) on power input receptacle (Figure 1, Item 6).
6.
Repeat Steps 1 through 5 for ECU (A).
POSITIONING ECU (B) FOR TRANSPORT MODE
1.
Remove four setscrews from ECU (B) transport location loor inserts and store in shelter Basic Issue Items
(BII) box (WP 0002 00, Figure 2, Item 5 or Figure 3, Item 6).
2.
Remove two cargo straps (Figure 3, Item 3) from secure storage location and four ring bolts (Figure 3, Item
4) from shelter BII box (WP 0002 00, Figure 2, Item 5 or Figure 3, Item 6).
3.
Install four ring bolts (Figure 3, Item 4) into loor inserts at transport location.
Figure 2.
Removing ECU (B) Hardware from ECU Fold-down Panel.
4.
Remove mounting hardware (Figure 2, Item 2) securing ECU (B) (Figure 2, Item 1) to fold-down panel (Figure
2, Item 3).
5.
Store hardware (Figure 2, Item 2) in shelter BII box (WP 0002 00, Figure 2, Item 5 or Figure 3, Item 6).