Figure 2. Wall and Floor Insert Inspection.
MAINTENANCE INSTRUCTIONS FOR BAYONET NEILL-CONCELMAN (BNC) CONNECTOR ASSEMBLY - Continued

Operator Manual For Tool Crib Shop Part No. 1036058 & Part No. Sc4920-99-Cla69
Page Navigation
  175    176    177    178    179  180  181    182    183    184    185  
img
. . .
TM 1-4920-441-13&P
0044 00
FIELD MAINTENANCE
TOOL CRIB SHOP
MAINTENANCE INSTRUCTIONS FOR BAYONET NEILL-CONCELMAN (BNC) CONNECTOR ASSEMBLY
INITIAL SETUP:
Personnel Required
Tools and Special Tools
CMF 15 Series (1)
Electrical Repairers Tool Kit
Equipment Condition
(WP 0059 00, Table 2, Item 103 )
Functional
Multimeter (WP 0059 00, Table 2, Item 106 )
WARNING
HIGH VOLTAGE exists in electrical system of shop. All electrical inspections, repairs, or
replacements will be performed with power OFF and only by a qualiied electrician. Serious
shock hazards exist which could result in INJURY OR EVEN DEATH to personnel.
NOTE
During installation of components same hardware should be used so as to maintain the original
integrity of the shop set.
INSPECTION OF INSTALLED ITEMS
Figure 1.
Inspect and Test BNC Connector Assembly.
1.
Move main circuit breaker to OFF position.
0044 00-1