Table 1. Operator Troubleshooting (cont'd)
Malfunction
Test or inspection
Corrective action required
Inspect to ensure all
Remove bolts. Using 2X4 or similar
securing bolts have been
23. Unable to Remove Pallet
object, tap upward on the drawer
removed. Check pallet
Ledge Assembly From Vertical
ledge until clear of vertical rack frame
ledge position to ensure it is
Rack Frame.
clear of the vertical rack
00.)
stanchion windows.
Remove and reposition with all pallet
ledge tabs inside vertical rack frame
24. Unable to Install Pallet Ledge
Inspect pallet ledge tabs to
windows and tap downward with a
Assembly onto Vertical Rack
ensure they are inside
2X4 or similar object until bolt holes
Frame.
vertical rack frame windows.
0033 00.)
25. Male Parachute Clips on Nets
Check the orientation of net
Turn net to orientate properly. (Refer
Do Not Align with Female Clips on
to ensure it is proper fitted.
Drawer/Pallet.
26. Safety Snaps on Floor Nets
Check orientation of net to
Turn net to orientate properly. (Refer
Will Not Stretch Between Rings at
ensure it is proper fitted.
Bottom of Vertical Rack Frames.
While pulling inward on the tension
release bar completely straighten
handle is in its full open
Mechanism.
handle until tension is released.
position.
Check module adapter plate
Clean as necessary. Insert rubber
cradles for debris. Check
pads as necessary. Check module
floor adapter plate cradles to
28. Unable to Insert Module and
locking arm for obstructions. Clear if
ensure rubber pads are in
Lock In Position.
necessary and fully extend outward to
place. Check module
its full open position. (refer to WP
locking arm to ensure it is in
the full open position.
Check module locking arm
Extend module locking arm to its full
29. Unable to Remove Module.
to ensure bit is in its full
open position. (refer to WP 0007 00)
open position.
Inspect for an obstruction
Clear obstruction and open.
inside the drawer. Visually
30. Unable to Open Module
inspect to ensure slam latch
and open slam lock until it disengages
Drawers.
is being completely opened
from lock striker and pull drawer
and is disengaging the lock
striker.
Inspect for an obstruction
inside the drawer. Visually
Clear obstruction and open. Fold
31. Unable to Close Module
inspect to ensure drawer
drawer locks completely into drawer
Drawers.
locks are in their closed
position.
0013 00-4