TM 10-5411-236-13&P
0013 00
Table 1. Operator Troubleshooting (cont'd)
Malfunction
Test or inspection
Corrective action required
Swing tab locks upward to clear back
Inspect basket tab locks to
of module and push basket
32. Unable to Install Module
completely inward until lock tabs can
ensure they are in the open
Basket.
position.
be position behind to lip on the back
of module.
Swing tab locks upward to clear back
Inspect basket tab locks to
of module and pull basket outward
33. Unable to Remove Module
ensure they are in the open
Basket.
until completely clear of module
position.
basket track. (Refer to WP 0007 00.)
Check to ensure that both
gate lock handles are
Pull both gate lock handles inward
until completely clear of the lock
34. Unable to Open Module
completely free of the lock
Basket Doors.
receptacle. Move cargo to free doors.
ensure cargo is not
restraining doors.
Inspect for an obstruction in
the path of the basket gates.
Clear obstruction and close doors.
35. Unable to Close Module
Check to ensure that basket
Completely retract and close door.
Basket Doors.
gate locks are completely
retracted.
Visually inspect to ensure all
36. Unable to Remove Module
Remove all remaining screws. (Refer
eight " mounting screws
Drawers.
are removed.
Visually inspect to ensure
that all eight ledge nuts
37. Unable to Install Module
Install ledge nuts as necessary.
Drawers.
located on the drawer slides
are installed.
Check to ensure plugs are
aligned with receptacle
Rotate plug to align with mating
receptacle and insert. Clean and
38. Unable to Connect AC Power
holes. Check for debris.
Cables
insert. Connect to proper AC
Inspect to ensure the cord or
receptacle is for AC power
not DC power.
Check to ensure plug s are
Rotate plug to align with mating
aligned with receptacle
39. Unable to Connect DC 9-Foot
holes. Check for debris.
receptacle and insert. Clean and
insert. Connect to proper DC
Power Cables
Inspect to ensure the cord or
receptacle is for DC power
not AC power.
0013 00-5