Table 2. Unit Maintenance Troubleshooting
Malfunction
Test or inspection
Corrective action required
Connector Kit
Both sides of Tandem-Loc
Tighten Tandem-Loc locking bolts as
1.Containers Separate When Lifting
correctly installed
Electrical Systems
A/C System
Interior Electrical Outlets
Check the GFCI reset
Depress the GFCI reset button.
2. No Power from the GFCI Outlet
button. Check the PDISE
Reset the PDISE circuit breakers.
circuit breakers
D/C System
Lighting Fixtures
Check the PDISE circuit
Reset the PDISE circuit breakers
3. Lights Fail to Operate
breakers. Check all FPU
8/12 cable connections
Check florescent tubes for
Replace florescent tubes. (Refer to
4 Florescent Light Fails
proper installation and
alignment with contacts
Trailer Adapter
Check Trailer Connection
Remove dirt/debris. (Refer to WP
Adapter Plug for dirt/debris
0005 00.)
5. Unable to Secure FPU to Trailer
Check for presence of
Install Adapter Plug. (Refer to WP
Adapter Plug
END OF WORK PACKAGE