TM 5-3610-256-14
Section V. TROUBLESHOOTING PROCEDURES
3-15. TROUBLESHOOTING TABLE. Proper troubleshooting procedures require that preliminary
checks be accomplished, all connections be tight and secure, and safeguards be utilized to prevent
excess ammonia vapor from entering the working area.
3-16. SCOPE. This manual cannot list all of the possible malfunctions or every possible test,
inspection, or corrective action. If a malfunction is not Iisted or not corrected by the Iisted
corrective actions, notify your supervisor.
Table 3-3. Organizational Troubleshooting
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1.
MACHINE WILL NOT RUN.
Step 1. Check plug at receptacle.
Reconnect plug.
Step 2. Check main power source.
Restore power.
Step 3. Inspect for defective wiring harness.
Refer to next higher level of maintenance for repair.
Step 4. Inspect for defective receptacle.
Replace receptacle (see paragraph 3-17).
Step 5. Inspect for blown main fuse.
Replace main fuse (see paragraph 3-19).
Step 6. Inspect for defective fuseholder.
Refer to next higher level of maintenance for repair.
2.
LAMPS LIGHT. MACHINE WILL NOT RUN.
Inspect drive fuse.
Replace fuse (see paragraph 3-19).
3-31