TM 5-3610-256-14
Section VI. ORGANIZATIONAL MAINTENANCE PROCEDURES
Page
Adjust Refeed Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-41
Replace Fuses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-40
Replace Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-36
Replace Receptacle . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-35
Service Condensation Bottle . . . . . . . . . . . . . . . . . . . . . 3-41
3-17. REPLACE RECEPTACLE.
TOOLS: Flat-Tipped Screwdriver
Cross-lipped Screwdriver
SUPPLIES: Receptacle
Unplug power cord before servicing machine. Death or injury may result
from failure to comply with this warning.
a. Power OFF.
b. Unplug power cord.
c. Remove rear cover.
d. Remove screws (1) and Iockwashers (2) to remove receptacle (3).
e. Install new receptacle (3) and secure with screws (1) and Iockwashers (2).
f. Reinstall rear cover.
g. Plug in power cord.
h. Power ON.
i. Perform operational test.
3-35