TM 5-3610-256-14
Table 3-3. Organizational Troubleshooting (Continued)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
3.
4.
POOR DEVELOPMENT.
Step 1. Check to see if ammonia supply is low,
Replenish ammonia (see Table 3-2).
Step 2. Test if ammonia is too weak.
Replace as required (see Table 3-2).
Step 3. Inspect ammonia tubing.
Reconnect tubing; no bends or kinks (refer to
Chapter 1 for routing of tubing).
Step 4. Inspect pump/motor for sluggish or noisy operation.
Refer to next higher level of maintenance for repair.
POOR QUALITY PRINTS OF CLEAR ORIGINAL.
Step 1. Inspect and test for weak or burned out lamps.
Replace lamps (see paragraph 3-18). If lamps burn out frequently, inspect
blower assembly. Refer to next higher level of maintenance for repair.
Step 2. Confirm correct diazo material is used.
Use correct papers in correct manner (see paragraphs 2-9 and 2-11).
Step 3. Check shelf life of diazo material.
Replace paper.
Step 4. Inspect for dirty cylinder.
Clean cylinder (see Table 3-2, item 5).
Step 5. Inspect sprockets.
Refer to next higher level of maintenance.
3-32