DO NOT REVERSE the hoses leading from the pump to the ammonia
supply bottle. This will cause pumping Iiquid ammonia or absorber into
the system, resulting in instant and total equipment contamination.
Should this condition exist, it will be necessary to thoroughly
clean the pump, valve assembly, developer tank, and tubing to render
the equipment operable.
The correct position of the tubes in the ammonia supply bottle indicated
below are not to be changed. Pushing the suction tube down into the
ammonia will cause liquid ammonia to be drawn up into the developer
tank. This will result in strong ammonia vapors and possible machine
damage.
1. Check ammonia absorber (see Table 3-2).
m. Reinstall right and rear covers.
n. Plug in power cord.
o. Power ON.
p. Perform operational test.