c.
Repair or Replacement Refer to paragraph 6-
3.c. for general repair or replacement procedures.
(1)
Replace damage or defective nipples,
couplings and gauges.
(2)
Replace all threaded parts having worn,
stripped or damaged threads.
(3)
Replace damaged or defective tubing or
flex hoses.
(4)
Replace damaged or defective fittings.
(5)
Replace identification plates If damaged or
if markings are illegible.
(6)
Straighten bent or dented panel (sheet
metal).
(7)
Replace all parts that are worn or damaged
to an extent that will Impair their normal
function.
d.
Cleaning
(1)
All parts or components of parts that make
up the Type II Oxygen System shall be
oxygen leaned prior to their assembly.
(2)
Parts shall be cleaned and handled in a
contaminant free environment.
e.
Assembly. To assemble the Type 11, Oxygen
Section of the control panel, proceed as follows (see
Figure 7-5).
All components and parts of the oxygen
system shall be oxygen clean, and shall
be assembled in a clean contamment
free
environment
using
approved
oxygen clean assembly procedures.
(1)
Install manifold pressure gauge (24, Figure
7-5, Sheet 1 of 2) and secure to panel using
gauge mounting screws and nuts.
(2)
Install the oxygen regulator pressure gauge
(23) and secure to panel using gauge
mounting screws and nuts.
(3)
Using screws (21) attach the oxygen
pressure
regulator (22) to the panel, place regulator
handle on stem and secure with the stem
nut, install pop-off cap in the handle.
NOTE
Install all tubing before fully tightening
valves and manifolds.
(4)
Insert the rear section of the valves (20)
with washers (25) through the back of the
panel, insert the stem of the front section of
the valve into the valve from the front of the
panel and secure valve by tightening the
retaining nut.
(5)
Install connectors (19, 22 and 27) in supply
and scuba manifolds (24, 28, Figure 7-5,
Sheet 2 of 2) Install the connectors as per
Figure 7-5 Sheet 2 of 2). Install safety
valves (21) on connectors (22) Position
manifold mounts (20) on manifolds (24, 28).
Using washers (19, Figure 705, Sheet 1 of
2) and screws (18) Install the manifolds on
the control panel.
(6)
Install adapter (16, Figure 7-5, Sheet 1 of 2)
to the oxygen recharge panel mount (23,
Figure 7-5, Sheet 2 of 2). Using screws
(17, Figure 7-5, Sheet 1 of 2) install panel
mount to the panel. Screw cap (15) on
adapter (16).
(7)
Install cam lever valves (14) with washers
(18) through the rear of the panel and
secure to panel using the valve holddown
nut
(8)
Using gauge mounting screws and nuts,
install oxygen cylinder pressure gauge (13).
(9)
Position and connect scuba manifold to
scuba
manifold
pressure
gauge
tube
assembly (11, Figure 7-5, Sheet 2 of 2)
Position and connect scuba manifold to
charging valve tube assemblies (10).
(10) Position and connect scuba manifold to
bleed valve tube assembly (9).
(11) Position and connect shut-off valve to
scuba manifold tube assembly (8).
(12) Position and connect pressure regulator to
scuba
manifold
shut-off
valve
tube
assembly (6).
6-12