TM 55-4920-402-13&P
(8) Test Balancer with double interrupter as fol-
lows:
(a) Run Tester at 1800 RPM and push and
hold TEST button on Phazor section.
Verify that the 12:00, 6:00, and 1:00
Oclock lamps light.
(b) Release TEST button and observe
clock angle of lighted lamp.
(c) push and hold VERIFY TUNE button
and adjust RPM TUNE dial to return
light to clock angle observed in above
step.
(d) Release VERIFY TUNE button and observe
new clock angle. Repeat until there is no
change whether VERIFY TUNE button is
pressed or released. Read clock angle with
the VERIFY TUNE button released. After
tuning, verify that the Phazor indicates
between 2:30 and 3:30 oclock, the IPS
meter reads between 0.72 and 0.88 IPS,
and the RPM TUNE dial reads between
176 and 184 RPM.
(e) Change RPM RANGE switch to Xl and
RPM TUNE dial to 900. Set Tester CAM
RATE switch to 900 RPM. Repeat steps
(a) through (d), above. Verify that the
IPS meter reads between 0.36 and 0.44 IPS
and RPM TUNE dial reads between 882 and
918 RPM.
(9) Test Balancer with single interrupter as fol-
lows:
(a)
(b)
(c)
(d)
(e)
(f)
Set INTERRUPTER LOGIC switch to
SINGLE. leave others as set in step (4).
Remove the two opposite pairs on interrupter
screws on the Tester (four total) leaving only
the two opposite single screws. Set tester
motor switch to ON.
Set Tester CAM RATE (RPM) and
Balancer RPM Tune to 1800 RPM.
RPM RANGE to X10 and push an hold
TEST button on Phazor. Verify that
only the 12:00 or 12:30 clock lamp
lights.
Release the TEST button and observe clock
angle of lighted lamp.
Push VERIFY TUNE button and adjust
RPM TUNE dial to return lamp to clock
angle observed before button was pushed.
Release VERIFY TUNE button and observe
new clock angle. Repeat until there is no
change between button pushed and released.
Verify that the indication in the Phazor
lights is between 8:30 and 9:30 oclock,
the IPS meter reads between 0.72 and 0.88
IPS, and the RPM TUNE dial reads between
176 and 184 (1800 RPM).
(g) Set Tester CAM RATE (RPM) and
Balancer RPM TUNE to 900 RPM.
RPM RANGE to X1. Repeat steps (c)
through (f) above. Verify that the IPS
meter reads between 0.36 and 0.44 IPS
and the RPM TUNE meter reads bet-
ween 882 and 918 RPM.
b. Adjustments. No adjustments can be made.
3-6. Strobex Checkout. The Strobex is checked by the
tester using Balancer unit. If the Balancer and Strobex
checks are not within specifications perform
paragraph 3-8 below:
a. Performance Check of the Balance Mode.
(1)
(2)
(3)
(4)
(5)
Connect VIBREX and Tester as shown in figure.
3-1.
Set Tester CAM RATE switch to 1800 RPM.
Set Balancer FUNCTION switch to
A or B. Set Balancer RPM TUNE
to 180 and set balancer RPM range
switch to the X10 scale. All other
controls are unimportant.
Set Strobex MODE switch to A.
Set Tester rotor for double interrupter (all six
interrupter screws installed, fig. 3-3).
NOTE
The Magnetic Pickup is not required, but
it need not be disconnected.
(6) Set Tester MOTOR switch to ON and
illuminate Tester rotor with the
Strobex. Verify that the stem of the h
in the logo appears stopped in two
positions.
(7) Note the clock angle of the stem of the
h in the logo. Push and hold VERIFY
TUNE button and adjust RPM TUNE
dial to return images to clock angle
observed before button was pushed.
Release VERIFY TUNE button and
observe new clock angle. Repeat until
there is no change whether VERIFY
TUNE button is pushed or released.
When the Balancer is properly tuned,
the stem of the h in the logo at the
center of the disc appears stopped and
double at 1:30 and 7:30 Oclock (fig. 3-
4).
(8) Set Tester CAM RATE (RPM) and
Balancer RPM TUNE to 900 RPM
RANGE to Xl. Observe the same
results as in step (7).
b. Performance Check of the Track Mode.
(1) Set Balancer MAGNETIC PICKUP switch to
COMMON, FUNCTION switch to TRACK, and
INTERRUPTER LOGIC switch to DOUBLE.
All other controls are unimportant.
Change 4
3 -5