TM 9-4933-223-13&P
13-15. SHOP SET--DOOR MODIFICATION--MAINTENANCE INSTRUCTIONS (cont)
MODIFICATION OF DOOR
NOTE
Steps 1 and 2 are used only for initial installation if the
shelter or personnel door are replaced with new parts.
1
PERSONNEL DOOR (1).
Table 3-4.
a. Drill four 0.391-in. (0.993- cm) diameter holes (2) 1.50 in. (3.81
cm) deep in interior surface located per dimensions as
illustrated.
2
HONEYCOMB CELL WALL (4). Cut
through if it falls between 0.391-in.
(0.993-cm) diameter hole and either
0.125-in. (0.318-cm) diameter holes.
b. Drill two 0.125-in. (0.318-cm) diameter
holes (3) through inside skin on each
side of each 0.391-in. (0.993-cm)
diameter hole as illustrated.
3-154