TB 9-4940-314-30
Section III. INSTALLATION IN ISO-2-1 SHELTER
loops, using six #10 x -in. counter-sunk head machine
NOTE
screws (MS5190-271).
Hand blind riveter (5120-00-679-65230 is used
to install blind rivet nuts in floors and walls of
d.
Follow steps (1) thru (17) below for equipment
ISO-2-1 shelter. Install blind rivet nuts in
installation in ISO-2-1 shelter, unit 2.
accordance with MIL-N-47187.
(1) Fabricate table
top
(11021224)
in
Position floor -, table top-, cabinet top-, and
wall- mounted equipment as shown in figures
Use the equipment
(2) Mark and drill four 0.42.in. diameter holes
mounting holes as templates for location of
in bottom plates of cabinets. Locate at the four corners,
blind rivet nuts and fasteners. Positions may
allowing for minimum required clearance for 5/16-in. hex
be varied to drill into structural members in
head capscrews.
fixed floor.
(3) Position three storage cabinets (7125-00-
a.
Mark and drill twelve 0.25-in. diameter holes in
991-2857) on right side of ISO-2-1 shelter fixed floor in
right side and front wall in accordance with figures 16
and 18. Install twelve #10 blind rivet nuts (11021235-5).
blind rivet nuts, in accordance with figure 15. Secure
storage cabinets to ISO-2-1 shelter floor, using twelve
b.
Mark and drill thirty-six 0.41-in. diameter holes
5/16- x 5/8-in. hex head capscrews (MS90725-31) and
in fixed and deployed floor in accordance with figures 15
and 19. Install four 5/16 blind rivet nuts (11021235-3) in
accordance with figure 15. Install thirty-two 5/16 blind
(4) Position table top (11021224) on top of
rivet nuts (11021235-1) in accordance with figures 15
three
storage
cabinets
(7125-00-991-2857)
in
template, mark and drill twelve 0.34-in. diameter holes
CAUTION
through tops of storage cabinets (four per storage
cabinet top). Secure table top to storage cabinet tops,
Potting compound, MMM-A-132, TYPE I,
using twelve 5/16- x 2-1/4-in. counter-sunk head
machine screws (MS35190-311), twelve 5/16in. flat
blind rivet nuts) must have a curing time of 24
to 48 hours before using any threaded
(MS35338-45), and twelve 5/16-in. hex nuts (MS51967-
fasteners.
5)
c. Install three strap loops (MS51939-3) over installed
(5) Position general mechanic tool kit (5180-00-669-
#10 blind rivet nuts on right side wall in accordance with
5273) on table top (11021224) in accordance with figures
16.
Secure
strap
14 and 16. Using strap loop (MS51939-3) as a
template,
mark and drill four 0.11-in. diameter pilot holes in table
top.
Secure
two
strap
12