Figure 3. Removal of Water Feedthru Connector Assembly.
Figure 6. Attach Water Feed-Thru Connector Assembly.

Operator Manual \(Rpstl\) For Pneudraulic Shop P/N Sc4920-99-Clc64 And Part No 1036258
Page Navigation
  200    201    202    203    204  205  206    207    208    209    210  
img
0052 00
TM 1-4920-433-13&P
INSTALLATION
WATER FEED-THRU CONNECTOR ASSEMBLY
Figure 4.
Water Feed-thru Connector Flange.
1.
Apply caulking compound on inside of water feed-thru connector assembly lange (Figure 4, Item 2) toward
long end of water feed-thru connector assembly (Figure 4, Item 1).
Figure 5.
Install Water Feed-thru Connector Assembly.
2.
Install new water feed-thru connector assembly (Figure 5, Item 1) from outside of shelter with long end
through hole.