Figure 2. Inspect 45 Degree Angle Adapter.
Figure 5. 45 Degree Angle Adapter Removal from Power Entry Panel Cover.

Field Maintenance Manual For Sheet Metal Shop Part No. 1035658 And Part No. Sc4920-99-A68
Page Navigation
  218    219    220    221    222  223  224    225    226    227    228  
img
0058 00
TM 1-4920-435-13&P
REMOVAL CONTINUED
45 DEGREE ANGLE ADAPTER CONTINUED
1.
Move main circuit breaker to OFF position.
2.
Remove four machine screws (Figure 3, Item 1) attaching 60 amp receptacle (Figure 3, Item 2) to 45 degree
angle adapter (Figure 3, Item 3).
3.
With machine screws (Figure 3, Item 1) removed, pull 60 amp receptacle (Figure 3, Item 2) out of 45 degree
angle adapter (Figure 3, Item 3) until wire lug terminals (Figure 3, Item 5) and wires (Figure 3, Item 4) are
exposed.
Figure 4.
45 Degree Angle Adapter Replacement.
NOTE
Replaced lugs are identiied by letters "X", "Y", and "Z" with ground connections being identiied
by color green. Black wire will be attached to "X", red wire will be attached to "Y", and blue wire
will be attached to "Z".
4.
Loosen all lugs (Figure 4, Item 3) on 60 amp receptacle (Figure 4, Item 1) and remove wires (Figure 4, Item
2).