TM 1-4920-435-13&P
0058 00
REMOVAL CONTINUED
45 DEGREE ANGLE ADAPTER CONTINUED
Figure 5.
45 Degree Angle Adapter Removal from Power Entry Panel Cover.
5.
Remove four machine screws (Figure 5, Item 5) from power entry panel cover (Figure 5, Item 1).
6.
Remove four nuts (Figure 5, Item 6), four lock washers (Figure 5, Item 2) and four bolts (Figure 5, Item 3)
which attach 45 degree angle adapter (Figure 5, Item 4) to power entry panel cover (Figure 5, Item 1).
INSTALLATION
45 DEGREE ANGLE ADAPTER
NOTE
Hardware for 45 degree angle 60 amp receptacle is provided by manufacturer.
1.
Insert 45 degree angle adapter (Figure 5, Item 4) by installing four bolts (Figure 5, Item 3), four lock washers
(Figure 5, Item 2) and four nuts (Figure 5, Item 6) to attach 45 degree angle adapter to power entry panel
cover (Figure 5, Item 1).
2.
Install four machine screws (Figure 5, Item 5) on power entry panel cover (Figure 5, Item 1).
0058 00-5