Figure 5. Disconnecting PDB from Generator.
REMOVING LIGHTING

Maintenance Manual For Production/ Quality Control Shop Part No. 1036659 And Part No. Sc4920-99-Cla66
Page Navigation
  114    115    116    117    118  119  120    121    122    123    124  
img
0032 00
TM 1-4920-440-13&P
REMOVING EXTERNAL GROUND ROD
NOTE
Shelter is grounded through externally connected power supply.
Figure 6.
Removing External Ground Rod.
1.
On power entry panel (Figure 6, Item 1), remove nut (Figure 6, Item 2), lock washer (Figure 6, Item 3), and
lat washer (Figure 6, Item 4) from ground stud (Figure 6, Item 7).
2.
Disconnect ground cable lug (Figure 6, Item 5) from ground stud (Figure 6, Item 7).
3.
Replace lat washer (Figure 6, Item 4), lock washer (Figure 6, Item 3), and nut on ground stud (Figure 6, Item
7).
4.
Remove grounding rod (Figure 6, Item 6) from earth.
5.
Store grounding rod assembly in secure storage location.
END OF WORK PACKAGE