REMOVING LIGHTING
Figure 3. Repositioning Ceiling Lights.

Maintenance Manual For Production/ Quality Control Shop Part No. 1036659 And Part No. Sc4920-99-Cla66
Page Navigation
  116    117    118    119    120  121  122    123    124    125    126  
img
0033 00
TM 1-4920-440-13&P
REMOVING CABLE AND RECEPTACLE ASSEMBLY
Figure 2.
Removing Cable and Receptacle Assembly.
1.
Release power cables from Velcro straps (Figure 2, Item 2).
2.
Release captive fasteners (Figure 2, Item 1) and reposition receptacles (Figure 2, Item 3) from operation
mode on hinged sidewall to transport mode on hinged end walls.
3.
Position receptacles (Figure 2, Item 3) with power cables facing upward and secure with captive fasteners
(Figure 2, Item 1).
4.
Repeat Steps 1 through 3 at opposite end of shelter.
0033 00-2