h. Plug the machine into a 110 V ac, grounded outlet. Turn power ON and dress feed switch. With a slight
pulling motion, remove the packing material which is wrapped around the cylinder.
i. After removing all packing material, turn power OFF and unplug power cord.
j. Refer to mounting hole (4) as indicated in illustration on previous page. Install the two
bearings as follows:
Remove the nut from the bearing assembly.
Screw bearing studs in each endplate mounting hole until tight.
Tighten nut inside the endhousings fingertight.
3-11. INSTALLATION OF AMMONIA AND ABSORBER SUPPLIES.
Ammonia vapor may cause injury or death. Do not breathe vapor.
Ensure adequate ventilation before servicing or operating Repro-
duction Set.
Ammonia may cause eye injury or blindness. Eye protection is
mandatory while servicing the ammonia system.
Ammonia may cause skin burns or irritation. Do net let ammonia
contact skin or clothing.
First Aid: If ammonia is spilled on skin, promptly wash with plenty
of water. Remove clothing if necessary to wash off affected area.
If eyes are affected, rinse with fresh water as soon as possible.
Continue for at least 15 minutes, Anyone overcome by ammonia fumes
should be removed to fresh air at once. Refer to FM21-11 and apply
artificial respiration. Use oxygen if breathing is labored or has stopped.
Obtain medical attention at once in cases of eye contact, burns to nose
or throat, or if person is unconscious.
3-8
Change 1