(8)
Straighten bent or dented panel.
(9)
Replace all parts that are worn or damaged
to an extent that will impair their normal
function.
e.
Assembly. To assemble the instrument panel
assembly, proceed as follows:
(1)
Insert indicator (43, Figure 8-8) through the
back of the panel (44), assemble indicator
cap on indicator and tighten.
(2)
Insert push button (42) through the back of
the panel (44), install push button cap and
tighten adjusting nut.
(3)
Remove retaining nut and washer from
unloader switch (39), insert the switch into
panel (44) from the back, install flat washer
and retaining nut. Tighten nut.
(4)
Remove the handles and locknuts from
hand valves (29, 33 and 37). Be sure flat
washers are in place and insert hand valves
through the panel from the back. Attach
locknuts and handles.
(5)
Connect tube assembly (17) at tee (27) and
tube assembly (5) at tee (31).
(6)
Connect service valve to service hose
bleed valve tube assembly (23).
(7)
Remove locknut from master switch (21).
Insert switch through back of panel (44),
attach locknut to switch (21) and tighten.
(8)
Install start switch (20) in panel (44) using
nuts (19) and screws (18).
(9)
Assemble wire assembly (17) to starter
switch (20).
(10) Install service outlet (16) in panel (44) using
nut (15). Tighten nut.
(11) Connect service outlet to service valve tube
assembly (14) at service outlet (16).
(12) Insert the compressor pressure gauge (3),
service pressure gauge (6), compressor oil
pressure gauge (8) and engine oil pressure
gauge in to panel (44). Attach clamps and
nuts to each gauge.
(13) Connect the service pressure to service
outlet tube assembly (5) at service pressure
gauge elbow (7).
(14) Install ammeter (2) into panel (44), attach to
panel with mounting clamps and nuts.
(15) Install hourmeter (1) into panel (44) with
mounting clamp and nuts.
6-12.
Rupture Disc Assembly (See Figure 8-9). The
following paragraphs contain disassembly, cleaning,
inspection,
repair
or
replacement
and
assembly
instructions for the rupture disc assembly.
a.
Disassembly. Disassemble the rupture disc
assembly only to the extent necessary to repair or
replace a defective part or parts.
(1)
Remove rupture disc base (8) from body
(10). Remove cap nut (9) from rupture disc
base (8) and remove washer and rupture
disc.
(2)
Remove connectors (5), elbows (4, 7) and
straight tee (6).
b.
Cleaning. Refer to paragraph 6-3.a. for general
cleaning procedures.
c.
Inspection. Refer to paragraph 6-3.b for general
inspection procedures.
d.
Repair or Replacement. Refer to paragraph 6-
3.c for general repair or replacement procedures.
e.
Assembly. To assemble the rupture disc
assembly, proceed as follows:
(1) Install straight tee (6), elbows (7, 4) and
connectors (5) to body (10).
(2)
If rupture disc and washer were removed
from the disc base (8) install and assemble
cap nut (9) to disc base (8). Install disc
base (8) in body (10).
6-13.
Air Cooler Group (See Figure 8-10.) The
following paragraphs contain disassembly, cleaning,
inspection
repair
or
replacement
and
assembly
instructions for the air cooler group.
a.
Disassembly. Disassemble the air cooler group
only to the extent necessary to repair or replace a
defective part or parts.
6-14