TM 5-4310-381-13
REMOVAL.
CAUTION
To avoid equipment damage, compressor must be shut down before
performing maintenance procedures.
a. If attached, remove air hoses (1) by pressing together and turning the two quick release fittings (2 and 3).
b. Remove quick release fittings (3) from elbows (4).
c. Remove elbows (4) with a pipe wrench.
d. Remove safety valve (5).
e. Remove pipe adaptors (6) from outlet tee (7).
f.
Remove outlet tee (7).
g. Remove pipe fitting (8) from air pump.
DISASSEMBLY.
a. Unscrew fitting (2) from adaptor (9).
b. Loosen hose clamps (10) and remove adaptor (9).
REPAIR.
a. Inspect rubber inserts (11 ) for cracks and damage. Replace as necessary.
b. Inspect rubber hose (1) for cracks and damage. Replace as necessary.
ASSEMBLY.
a. Install adaptor (9) to air hose (1) and tighten hose clamp (10).
b. Install fitting (2) to adaptor (9).
INSTALLATION.
a. Install pipe fitting (8) to air pump.
b. Install outlet tee (7).
c. Install adaptors (6) to outlet tee (7).
d. Install safety valve (5).
e. Install elbow (4).
f.
Install fitting (3) and elbow (4).
g. Install air hose(1) by pressing together and turning quick release fittings(2 and 3) until tabbed flanges meet.
3-10