TM 55-4920-213-15
Figure 2. Identification plates, Shop Set C-4.
Compressor mount-
ing_ _ _ _ _ _ _ _ _ _ _ _ _ Bolt down (fig. 56).
Compressor
rating _ _ _ _ _ _ _ _ _ 5 cfm @ 175 psi.
Power supply
required_ _ _ _ _ _ _ _ 220 v, ac, three phase 60
cycle.
Pneumatic connec-
tions, shop _ _ _ _ Quick disconnect, air sup-
ply tank.
Saftey devices _ _ Safety relief valve, refer to
Controls_ _ _ _ _ _ _ _ _ Shut-off valve; oil and
water separator, gages,
regulators, valves, and
Pneumatic connec-
tions, Equip-
ment _ _ _ _ _ _ Quick disconnect fittings
Figure 3. Instruction plate, Shop Set, C-4.
(3) Utility system:
Controls- - - - - -Thermal-magnetic circuit
breaker panel; 14 break-
Type equipment_ _ _ Bench tops, maple, Size
A, C, and D. Storage
Electrical connec-
cabinets, types I, II, and
tions, Equip-
III.
Equipment
breakers.
functions _ _ _ _ _ _Bench tops, work area and
(2) Pneumatic system:
34, 35, and 36); storage
cabinets-storage of hand
tools and accessories.
cating, electric motor
Equipment
driven.
Compressor make
mounting _ _ _ _ _ _ Bench tops-bolt down ;
and model _ _ _ _ _ _ Military Specification MIL-
storage cabinets--bolt
C-13874, Class A, Style I.
down.
6