TM 9-4933-223-13&P
3-26.
CABLE ADAPTER ASSEMBLY--MAINTENANCE INSTRUCTIONS (cont)
PREPARATION OF CABLE FOR PLUG CONNECTOR
NOTE
The following procedure
is used only for initial
assembly or when the
cable, insulation, or
compression connector has
been replaced with a new
item.
1.
CABLE (1).
a. Cut ends square.
b. Remove 3 in. (7.62 cm) of
jacket (2) from end.
2.
FOUR GREEN WIRES (3).
a. Remove 1.50 in. (3.81 cm) of insulation.
b. Twist exposed end of wire.
3.
WHITE WIRE (4).
a. Remove 1.50 in. (3.81 cm) of insulation.
b. Twist exposed end of wire.
3-224