(10) Position the air cylinders (10) on frame rails
and push cylinders (10) as far forward as
they will go against the steel bulkhead
Secure air cylinders in place by thoroughly
tightening the clamping band holding the air
cylinders (10) to the frame (19) rails
(11) Attach flux hose assembly to the gas
cylinder valve (10)
6-6.
CONTROL PANEL ASSEMBLY, TYPE I (AIR)
(See Figure 7-4.) The following paragraphs contain
disassembly, cleaning, inspection, repair or replacement
and assembly instructions for the Type I control panel
assembly.
a.
Disassembly. Disassemble the control panel
assembly only to the extent necessary to repair or
replace a defective part or parts
NOTE
Tag tube assemblies for re-assembly
purposes
(1)
Disconnect and remove cam lever valve to
pressure gauge tube assemblies (1, Figure
7-4, Sheet 2 of 2).
(2)
Disconnect and remove cam lever valve to
supply manifold tube assembly (2)
(3)
Disconnect and remove recharge valve to
supply manifold tube assembly (3), and
supply manifold to supply manifold shut-off
valve tube assembly (3)
(4)
Disconnect and remove pressure regulator
to scuba manifold shut-off valve tube
assembly
(5)
Disconnect
and
remove
scuba manifold shut-off valve to scuba
manifold tube assembly (6).
(5)
Disconnect and remove service pressure
gauge to pressure regulator tube assembly
(7) Disconnect and remove scuba manifold
to manifold pressure gauge tube assembly
(8)
(6)
Disconnect and remove scuba manifold to
bleed valve tube assembly (6). Disconnect
and remove scuba manifold to charging
valve tube assemblies (9)
(7)
Loosen and remove gas cylinder pressure
gauge (1, Figure 7-4, Sheet 1 of 2)
mounting nuts and clamps Remove gauge
(1) from panel.
(8)
Loosen and remove cam lever valve (2)
hold down nut Remove valve from the rear
of the panel
(9)
Remove screws (3) and washers (4)
Remove the supply manifold and scuba
manifold (18, 26, Figure 7-4, Sheet 2 of 2)
and manifold mounts (25) from the rear of
the panel.
NOTE
Tag valves for re-assembly purposes
(10) Remove the nuts from the face of the
supply manifold shut-off valve (5, Figure 7-
4, Sheet 1 of 2), bleed valve (5), scuba
manifold shut-off valve (5), recharge valve
(5) and scuba charge valves (5) Remove
the handles and valve hold down nuts
Remove valves from the rear of the panel
(11) Remove nuts and clamp from scuba
manifold pressure gauge (1) Loosen and
remove nuts and clamp from the service
pressure gauges (6) Remove gauges from
the panel
(12) Remove pop-off cap from middle of air
pressure regulator (8) handle, remove nut
and handle, remove screws (7) from
regulator (8) and remove from rear of the
panel.
(13) Unscrew and remove cover (9), screws and
nuts securing air panel mount (21, Figure 7-
4, Sheet 2 of 2) to the panel Remove panel
mount (21), do not remove adapter (10,
Figure 7-4, Sheet 1 of 2) from panel mount
unless necessary.
Care shall be taken to insure that no
cleaning agent deposits are left on/in
components after the cleaning process
b.
Cleaning. Refer to paragraph 6-3 a for general
cleaning requirements
(1)
Wash glass gauge faces with a soft cloth
and warm soapy water, or equivalent Dry
with a clean lint-free cloth. Use care not to
damage gauges.
6-6