Figure 4. Ultrasonic Cleaner Generator, Brackets, and Hardware.
MAINTENANCE INSTRUCTIONS FOR ULTRASONIC CLEANER, GENERATOR, AND HARDWARE - Continued

Maintenance Manual For Engine Shop Part No. 1035258 And Part No. Sc4920-99-Cla60
Page Navigation
  157    158    159    160    161  162  163    164    165    166    167  
img
TM 1-4920-436-13&P
0037 00
INSTALLATION
1.
To install ultrasonic cleaner generator (Figure 4, Item 1), install four bolts (Figure 4, Item 4), four lock washers
(Figure 4, Item 3), and four lat washers (Figure 4, Item 2).
Torque bolts (Figure 4, Item 2) 160-190 in. lbs.
2.
INSPECTION OF INSTALLED ITEMS
ULTRASONIC CLEANER AND HARDWARE
Figure 5.
Ultrasonic Cleaner and Hardware.
1.
Inspect ultrasonic cleaner (Figure 1, Item 4) for damage. Replace as necessary.
2.
Inspect ultrasonic cleaner hardware (Figure 1, Items 1 through 3) for rust, cracks and rounded heads.
Replace as necessary.
REMOVAL
To remove ultrasonic cleaner (Figure 5, Item 1), remove four bolts (Figure 5, Item 4), four lock washers (Figure
5, Item 3), and four lat washers (Figure 5, Item 2).
INSTALLATION
1.
To install ultrasonic cleaner (Figure 5, Item 1), install four bolts (Figure 5, Item 4), four lock washers (Figure 5,
Item 3), and four lat washers (Figure 5, Item 2).