Figure 5-4. Dehydrators
g.
Place fresh cartridges/filters in the air
purification cylinders as follows (see Figure 8-2).
Cylinder
Cartridge
3
C-1-13X
4
C0-6
5
C-1-AC
CAUTION
Screw the cap assembly until snugly in
place.
h.
Screw
cylinder
caps
back
onto
the
cylinders. Apply enough force to cap assemblies to
pierce the cartridges with the built-in piercing blades.
After piercing blades have entered the cartridge, screw
cap assembly down firmly against the cylinder. Do Not
overtighten.
NOTE
Each
time
cartridges
or
filter
are
installed
Figure 5-5. Engine Fuel Filter
record
hourmeter
readings
on
applicable forms.
5-8.
Battery. To check the batterys state of charge,
proceed as follows:
WARNING
Wear goggles to prevent electrolyte front
coming into contact with eyes. To
prevent
serious
burns
wear
rubber
gloves and apron when filling battery.
a.
To top up the battery, ordinary tap water
may be used except in areas known to have a high
mineral or alkali content in the water. In these areas,
distilled water shall be used.
b.
The fluid level should be maintained at the
till to ring mark.