• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
MAINTENANCE INSTRUCTIONS FOR CABINET INTEGRATION HARDWARE - Continued
MAINTENANCE INSTRUCTIONS FOR EYEWASH STATION ASSEMBLY BRACKET AND HARDWARE - Continued

Aviation Maintenance Manual For Power Train Shop P/N 1036459 And P/N Sc492097Cla65
Page Navigation
  169    170    171    172    173  174  175    176    177    178    179  
img
. . . .
TM 1-4920-438-13&P
0042 00
FIELD MAINTENANCE
POWER TRAIN SHOP
MAINTENANCE INSTRUCTIONS FOR EYEWASH STATION ASSEMBLY BRACKET AND HARDWARE
INITIAL SETUP:
Personnel Required
Tools and Special Tools
CMF 15 Series (1)
General Mechanics Tool Kit
(WP 0067 00, Table 2, Item 104 )
References
Torque Wrench, 0-600 in. lbs
Sperian Fendall Pure Flow 1000 Eyewash Station
(WP 0067 00, Table 2, Item 109 )
Owner s Manual
Materials/Parts
Equipment Condition
Eyewash Station Removed
Fountain, Eye and Face Wash (WP 0073 00, Item 4)
INSPECTION OF INSTALLED ITEMS
NOTE
During installation of components same hardware should be used so as to maintain original
integrity of shop set.
Figure 1.
Eyewash Station.
1.
Inspect eyewash station bracket (Figure 1, Item 4) for damage. Replace as necessary.
2.
Inspect eyewash station bracket hardware (Figure 1, Item 1 through 3) for rust, cracks and rounded heads.
Replace as necessary.
REMOVAL
1.
If necessary, drain eye and face wash fountain solution IAW with Eyewash Station Owner s Manual.
2.
Remove two bolts (Figure 1, Item 1), two lock washers (Figure 1, Item 2), two lat washers (Figure 1, Item 3),
and eyewash station bracket (Figure 1, Item 4).
INSTALLATION
1.
Position eyewash station bracket (Figure 1, Item 4) by aligning bolt holes with wall inserts.
2.
Install two bolts (Figure 1, Item 1), two lock washers (Figure 1, Item 2), and two lat washers (Figure 1, Item
3).
Torque bolts (Figure 1, Item 1) 160-190 in. lbs.
3.
0042 00-1


Privacy Statement